Price
$1,891.00
$750+ Online Orders Ship Free via UPS Ground.
Call for Availability
SKU
750-890/040-000
750-890/040-000 Controller Modbus TCP; 4th generation; 2 x ETHERNET, SD Card Slot; Extreme
- Communications Modbus (TCP, UDP)
- ETHERNET protocolsHTTP(S)
- BootP
- DHCP
- DNS
- SNTP
- FTP(S)
- SNMP
- Visualization Web-Visu
- CPU 32 bits
- Programming languages per IEC 61131-3
- Instruction List (IL)
- Ladder Diagram (LD)
- Function Block Diagram (FBD)
- Continuous Function Chart (CFC)
- Structured Text (ST)
- Sequential Function Chart (SFC)
- Programming environment WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
- Configuration options
- WAGO-I/O-CHECK
- Web-Based Management
- CODESYS Library
- Baud rate (communication/fieldbus 1)10/100 Mbit/s
- Transmission rate 10/100 Mbit/s
- Transmission medium (communication/fieldbus) Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
- Transmission performance Class D per EN 50173
- Program memory 8 MB
- Data memory 8 MB
- Non-volatile software memory 32kbyte
- Type of memory card SD card
- Memory card slot Push-push mechanism; Cover lid (sealable)
- Number of modules per node (max.) 64
- Number of modules without a bus extension (max.) 64
- Input and output process image (fieldbus) max.1020 words/1020 words
- Indicators LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O, USR) red/green/orange: Local data bus status, status
- programmable by user; LED (A, B) green: System power supply status, field supply
- Derating
- Derating (supply voltage):
- Ambient temperatures under laboratory conditions: (−25 … +30 %);
- for −40 … +55 °C: 24 V (−25 … +20 %);
- for +55 … +70 °C: 24 V (−25 … +10 %);
- Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)
- Supply voltage (system) 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
- Input current (typ.) at nominal load (24 V) 500mA
- Power supply efficiency (typ.) at nominal load (24 V) 90%
- Current consumption (5 V system supply) 440mA
- Total current (system supply) 1,700mA
- Supply voltage (field) 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
- Current carrying capacity (power jumper contacts) 10A
- Number of outgoing power jumper contacts 2
- Rated surge voltage1 kV
- Connection technology: communication/fieldbusModbus (TCP, UDP): 2 x RJ-45
- Connection technology: system supply 2 x CAGE CLAMP®
- Connection technology: field supply 4 x CAGE CLAMP®
- Connection type 1 System/field supply
- Solid conductor 0.25 … 2.5 mm² / 24 … 14 AWG
- Fine-stranded conductor 0.25 … 2.5 mm² / 24 … 14 AWG
- Strip length 8 … 9 mm / 0.31 … 0.35 inches
- Connection technology: device configuration1 x Male connector; 4-pole
- Weight 149.9g
- Housing material Polycarbonate; polyamide 6.6
- Conformity marking CE
- Ambient temperature (operation) -40 … +70 °C
- Ambient temperature (storage) -40 … +85 °C
- Protection type IP20
- Pollution degree 2 per IEC 61131-2
- Operating altitude without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
- Relative humidity (without condensation) 95%
- Relative humidity (with condensation) Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
- Mounting position Horizontal left, horizontal up, vertical top and vertical bottom
- Mounting type DIN-35 rail
- Vibration resistance per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
- Shock resistance per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
- EMC immunity to interference per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26; EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
- EMC emission of interference per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
- Exposure to pollutants per IEC 60068-2-42 and IEC 60068-2-43
- Fire load 2.487MJ
- Permissible pollutant concentration H2S at a relative humidity < 75% 10ppm
- Permissible pollutant concentration SO 2 at a relative humidity < 75% 25ppm
| Is FM | No |
|---|