Wireless Instruments > Sensor/Transmitters > Honeywell XYR6000 STDW

 

Honeywell XYR6000 STDW Wireless Transmitter for Differential Pressure

Built on Honeywell's successful ST3000 series transmitters, the XYR6000 adds simple, safe, and secure wireless technology into the mix. XYR6000 series are part of the Wireless Network for Secure Industrial Applications (WNSIA)-compliant field devices.

All XYR6000 transmitters send information to a Honeywell Multinode, which can support up to 400 transmitters each, depending on the reporting frequency.

The STDW differential pressure transmitters can be used in a number of pressure measurement applications, from furnace combustion airflow rate to hydrostatic tank gauging. They can be used with any primary flow element to provide proven, repeatable flow measurements.

Key Specifications

  • Models with measurement ranges of 0 to 400"WC (STDW924), 0 to 100 psi (STDW930), or 0 to 3000 psi (STDW974)
  • ISA100 wireless compliant device
  • 2.4 GHz frequency hopping spread spectrum (FHSS) wireless communications
  • Transmitter range with integral antenna (shown) is 1000 feet line-of-sight
  • Accuracy greater of ±0.10% calibrated span or upper range value
  • Powered by two D Lithium batteries, expected lifetime of up to 10 years
  • Part of Honeywell's OneWireless universal mesh network system

Specifications, Manuals, and Supporting Literature

Click the file icon to view the file online, or right-click on the file icon and select "Save Target As..." to download the file to your computer for later viewing.
Tip: If you want to print a large file, download it to your PC first.

Model Selection Guide

Use this table to find the right model for your application.  Don't see the option you need? Call a Lesman sales specialist at 800-953-7626

Check any restriction letters or notes to be sure the unit is available.
A finished catalog number looks like this: ST _ W9_ _-_ _ _-00000-_ _ _ _ _-_ _, _ _, _ _-XXXX

Description Catalog Number Availability
Differential Pressure
(DP) Range
0-10" to 0-400" H2O to 0-1000 mbar
0-5 to 0-100PSI/0-0.34 to 0-210 bar
0-100 to 0-3000PSI/0-7 to 0-210 bar
STDW924
STDW930
STDW974
 
 
 


Material Process Head Vent/Drain Valve Barrier Diaphragm      
Carbon Steel
316 SS
316 SS
316 SS
Hastelloy C
316 SS
316 SS
316 SS
316 SS
Hastelloy C
316L SS
316L SS
316L SS
Hastelloy C
Hastelloy C
A _ _
E _ _
E _ _
F _ _
J _ _


 


 

 
 
Fill Fluid Silicone DC200
CTFE
_ 1 _
_ 2 _


Process Head 1/4" NPT
1/2" NPT with Adapter (on 1/4" NPT Head)
_ _ A
_ _ H

 

k
No Selection 00000
Antenna 2 dBi Integral Right-Angle, Vertical
2 dBi Integral Straight, Horizontal
4 dBi Integral Right-Angle, Vertical
8 dBi Remote Omnidirectional
14 dBi Remote Omnidirectional
V _ _ _ _
S _ _ _ _
R _ _ _ _
M _ _ _ _
D _ _ _ _
d
d
d
e
e
d
d
d
e
e
Cable A for Remote Antenna None
1M Remote Cable A, TNC-R-N
3M Remote Cable A, TNC-R-N
10M Remote Cable A, TNC-R-N
_ 00 _ _
_ 01 _ _
_ 03 _ _
_ 10 _ _






Cable B to Antenna,
Lightning Protection
None
Lightning Protection, 1M Cable B
Lightning Protection, 3M Cable B
Lightning Protection, 10M Cable B
_ _ _ 00
_ _ _ 01
_ _ _ 03
_ _ _ 10






Radio 2.4 GHz FHSS
2.4 GHz DSSS, 802.15.4
ISA 100.11a 2.4 GHz DSSS-FH, 802.15.4
XF
XD
XS




Power Battery
24 VDC (Not ATEX/IEC/SAEx Approved)
BA
DC


Custom Calibration, ID in Memory CC
Transmitter Configuration, ID in Memory TC
Stainless Customer Wired-On Tag TG g g
NACE A286SS Bolts, 304SS Nuts for Process Heads CR
316SS Nuts and Bolts for Process Heads SS
316SS 1/2" NPT Adapter Flange, Carbon Steel Bolts S2 c c
316SS 1/2" NPT Adapter Flange and Bolts S3 c c
Hastelloy C 1/2" NPT Adapter Flange, 316 SS Bolts T3 c c
Side Vent/Drain (End Vent/Drain Std.) SV
Carbon Steel Transmitter Mounting Bracket MB
304 SS Transmitter Mounting Bracket SB
Printed Copy of User's Manual UM
Clean Transmitter for Oxygen or Chlorine Service 0X h h
F3399 Calibration Test Report, Cert of Conformance F1
1 Year Warranty Extension W1
2 Year Warranty Extension W2
Approval Type Location/Classification      
No Hazardous Locations Approvals 9X
FM Intrinsically Safe, Explosion-Proof,
Non-Incendive and Non-Sparking
1C
CSA
us
Intrinsically Safe, Explosion-Proof,
Non-Incendive and Non-Sparking
2C

Restrictions
b Select only one option from this group.
c Available only with Process Head option _ _ G
d Available only with antenna and cable options _ 0000
e Requires a Cable A option (01, 03 or 10)
g Customer-supplied tag information, four lines, 28 characters per line
h Available only with fill fluid CTFE (_ 2 _)
k Available only with material options S2, S3, and T3

Videos

Subscribe to the Lesman Instrument Company YouTube channel.Lesman Instrument Company on YouTube

Video is a great way to learn about instruments and technology, and it's available whenever you need it. Watch step-by-step instructions on how to configure a transmitter, tune a controller, or troubleshoot a safety valve. We'll post videos we create, and those our manufacturer partners share with us, so you don't have to look in multiple places to find the video training you need.