Honeywell SmartLine STD800 Modular Differential Pressure Smart Transmitters

In the 1980s, Honeywell introduced the world's first smart transmitters. In 2012, they're introducing the latest in smart transmitter technology: a fast-responding, high accuracy, modular transmitter series, designed to improve value across your entire plant lifecycle.

Honeywell SmartLine ST800 transmitters can help you reduce project costs, cut startup and commissioning time, lower total maintenance costs, reduce repair time, enhance safety, lower operating costs, reduce unplanned downtime, and improve product quality.

SmartLine ST800 transmitters are designed to replace older ST3000 Series 100 transmitter models. To replace or upgrade an ST3000 Series 900 model, see the new Honeywell ST700.

Key Specifications

  • Rangeability and turndown of up to 400:1
  • Response times as fast as 80 ms (the fastest on today's market)
  • Reference accuracy to 0.0375% span standard (0.025% span optional), and a total probably error as good as 0.12%
  • Transmitter stability up to 0.01% span per year for 10 years
  • Built-in static pressure and temperature compensation
  • External zero, span, and configuration capabilities
  • Polarity-insensitive electrical connections
  • Comprehensive onboard diagnostics
  • Plugged impulse line detection option
  • Dual or triple calibration option
  • Full compliance to SIL2 and SIL3 requirements standard
  • Advanced graphic LCD: Eight configurable screens for process variables, bargraphs, and trends
  • Modular design makes it easy to change communication modules, digital displays, and replace hardware or meter body — without buying a new unit!

Specifications, Manuals, and Supporting Literature

Click the file icon to view the file online, or right-click on the file icon and select "Save Target As..." to download the file to your computer for later viewing.
Tip: If you want to print a large file, download it to your PC first.

Model Selection Guide

Make on selection from each table section below. A finished catalog number
looks like this: STD8_ _ - _ _ _ _ _ _ - _ - _ - _ _ _ - _ _ _ - _ - _ _ _ _ - _ _ - 0000

Description Catalog
Number
Availability
Model
Range Limit
(Span)
- 10 to 10" H2O (0.1 to 10" H2O)
-400 to 400" H2O (1.0 to 400" H2O)
-100 to 100 PSI (1 to 100 PSI)
-100 to 3000 PSI (30 to 3000 PSI)
STD810-
STD820-
STD830-
STD870-

 
 
 
 

 
 
 
 

 
 
 
 
Meter body Plated CS Head, 316L SS Diaphragm
316 SS Head, 316L SS Diaphragm
A _ _ _ _ _ _ -
E _ _ _ _ _ _ -

 



Fill Fluid Silicone Oil (DC 200)
Flourinated Oil CTFE
_ 1 _ _ _ _ _ -
_ 2 _ _ _ _ _ -

 



Process
Connection
None
1/2" NPT Female
_ _ A _ _ _ _ -
_ _ H _ _ _ _ -




Bolt/Nut
Materials
Carbon Steel
316 SS
Grade 660 (NACE A286) NACE 304 SS Nuts
_ _ _ C _ _ _ -
_ _ _ S _ _ _ -
_ _ _ N _ _ _ -








Head Type/
Vent/Drain
Position
Single Ended
Single Ended, Side Drain and Vent
Single Ended, Side Drain, Center SS Vent
Dual Ended, End Drain, and Vent
Dual Ended, End Drain, Center SS Vent
Dual Ended
_ _ _ _ 1 _ _ -
_ _ _ _ 2 _ _ -
_ _ _ _ 3 _ _ -
_ _ _ _ 4 _ _ -
_ _ _ _ 5 _ _ -
_ _ _ _ 6 _ _ -




















Gasket Teflon® or PTFE (Glass Filled)
Viton® or Fluorocarbon Elastomer
Graphite
_ _ _ _ _ AS -
_ _ _ _ _ BS -
_ _ _ _ _ CS -








Head/
Connection
Orientation
High Side Left, Low Side Right
Low Side Left, High Side Right
High Side Left, Low Side Right, 90° Head Rotation
1 -
2 -
3 -








Approvals No Approvals Required
FM Approved
CSA Approved
ATEX Approved
0 -
A -
B -
C -








Electric
Housing
1/2" NPT Aluminum
1/2" NPT Aluminum with Lightning Protection
A _ _ -
C _ _ -




Outputs 4-20mA DC and HART®
4-20mA DC and Honeywell DE
_ H _ -
_ D _ -




Indicator
and
Interface
No Indicator or Buttons
No Indicator, External Zero/Span Buttons
Indicator
Indicator, External Zero/Span/Config. Buttons
_ _ 0 -
_ _ A -
_ _ B -
_ _ C -












Failsafe/
Write Protect
Fail Mode High
Fail Mode Low
Fail Mode High, Write Protect Enabled
Fail Mode Low, Write Protect Enabled
11S-A
12S-A
13S-A
14S-A












Mounting
Bracket
None
Angle Bracket, Carbon Steel,
Angle Bracket, 304SS
Flat Bracket, Carbon Steel
Flat bracket, 304SS
0 _ _ _
1 _ _ _
2 _ _ _
5 _ _ _
6 _ _ _
















Tagging None
One Wired SS Tag (4 lines x 26 char/line)
Two Wired SS Tag (4 lines x 26 char/line)
_ 0 _ _
_ 1 _ _
_ 2 _ _








Conduit
Plugs/
Adapters
None
1/2" NPTM to 3/4" NPTF 316 SS Conduit Adapter
1/2" NPT 316 SS Certified Conduit Plug
Minifast® 4 Pin (1/2" NPT) (not for X-Proof use)
_ _ A0
_ _ A2
_ _ A6
_ _ A8












Certificates F3399 Calibration Test & Certificate of Conformance
F0195 Certificate of Origin
FC33337 FMEDA (SIL 2/3) Certification
F1
F5
FE


j


j


j


j
Documentation Printed English User Manual
HART/DE Communications Manual
Safety Manual
Function Block Manual
34-ST-25-35
34-ST-25-38
34-ST-25-37
34-ST-25-42












Restrictions
j Available only with HART® digital output; Requires write protection enabled

Videos

Subscribe to the Lesman Instrument Company YouTube channel.Lesman Instrument Company on YouTube

Video is a great way to learn about instruments and technology, and it's available whenever you need it. Watch step-by-step instructions on how to configure a transmitter, tune a controller, or troubleshoot a safety valve. We'll post videos we create, and those our manufacturer partners share with us, so you don't have to look in multiple places to find the video training you need.

Subscribe to Lesman's YouTube channel, and you'll get email notifications as soon as we add new training videos and webinars.