Choosing the Right Honeywell Circular Chart Recorder

Honeywell Honeywell DR4300 10" Circular Chart Recorder
DR4300 10" Circular
Honeywell DR4500 Classic 12" Circular Chart Recorder
DR4500 Classic 12" Circular
Honeywell DR4500 Truline 12" Circular Chart Recorder
DR4500 Truline 12" Circular
Chart 10" Circular
Choose from 150 Preprinted Charts
12" Circular
Your Choice of 5,000 Preprinted Charts
12" Circular; Prints its Chart as it Records! With user-configurable data (date, time, process ID) directly on the chart!
Input Features Up to 2 T/Cs: Type J, K, R, S, T; RTDs: Pt100Ω; 0-200 mV; 0-1, 0-5, 1-5, or 0-10 VDC; Optional Model: T/Cs: B, E, W5W26, NiNi Moly Up to 2 T/Cs: J, K, R, S, T, B, E, W5W26; RTDs: Pt100Ω, Pt500Ω; Linear: 4-20 mA, 0-10 or 10-50 mV, 1-5 or 1-10 V Up to 4 T/Cs: J, K, R, S, T, B, E, W5W26; RTDs: Pt100Ω, Pt500Ω; Linear: 4-20 mA, 0-10 or 10-50 mV, 1-5 or 1-10 V
Accuracy ±0.35% Span Standard, ±0.1% Span (Field Calibrated) ±1°F for T/Cs, ±1% or Better for Voltage Ranges
Digital Input 2 with Control 2
Alarms 2 per Pen 2, 4 or 6
Auxiliary Output 1 per Pen 1-3
Communications 3rd Party Ethernet Bridge, Limited Modbus RTU, RS485 3rd Party Ethernet Bridge, Modbus RTU, RS485
Controllers 1 per Pen 1 or 2 2 (4-20mA) Pulse Output
Autotune Accutune II Accutune II Accutune II
Control Features On/Off, Duplex, PD with Manual Reset Cascade, Duplex, Position Proportional, Universal Output Cascade, Duplex, Position Proportional, Universal Output
Door NEMA 3/IP66 NEMA 3, NEMA 4X Door Optional
Programmers 1 per Pen, 4 Profiles, 24 Segments Standard with Control, 6 Profiles, 36 Segments
Sample Rate 0.3 Seconds 0.3 to 0.7 Seconds
Software Programs SpecView SpecView, Prosoft
Added Functionality Timers, One Totalizer per Pen, 24 VDC Power, Optional Two-Line Display for Viewing PV, Setpoint, Control Output, Deviation from Setpoint Totalization of Both Channels, Timers, Setpoint Programming with Real-Time Clock, Auxiliary 4-20 mA Output, Integral 24 VDC Power Supply Provides Loop Power for Up to Two Transmitters Totalization on All Channels, Timers, Setpoint Programming, Auxiliary 4-20 mA Output, Math Functions (Mass Flow, BTU, Fo Sterilization), Message Printing, Integral 24 VDC Power Supply, Real-Time Clock, Up to 6 Relays, HTST, Dairy and Pasteurization Models Available
Approvals Approvals: UL, FM, CSA Approvals: CE, FM, UL, CSA Approvals: CE, FM, UL, CSA
Buy Online at Lesman DR4301 Basic Single Pen Recorder
DR4311 Single Pen Recorder with Display
DR4302 Basic Two-Pen Recorder
DR4312 Two-Pen Recorder with Display
 
Honeywell 10" Circular Charts
DR4500 Classic Two-Pen Recorder
 
Honeywell 12" Circular Charts
Chart Pens, Hub Kits, and Motors
DR45AT Standard Truline Recorder
DR45AR Truline Relay Expansion Recorder
DR45AT Truline HTST Recorder
Charts, Pen Arms, Hub Kits, and Motors
 
Popular Models Available from Lesman Stock