Transmitters > Flow/Mass Flow > Honeywell SMV800

 

Honeywell SMV800 SmartLine Multivariable Transmitter

Honeywell’s SMV800 SmartLine multivariable transmitter simultaneously measures three separate process variables according to standard industry methods for air, gases, steam, and liquids. The transmitter can also calculate compensated mass or volume flow rate as a fourth process variable.

The SMV800 combines integrated sensor and microprocessor technologies, as well as dynamic flow compensation, to produce the most accurate and consistent flow measurement possible. The transmitter can measure differential pressure across a primary flow element (averaging pitot tube, venturi, flow nozzle, orifice plate, V-Cone®, wafer cone, or wedge); static process pressure from a single sensor; and process temperature from thermocouple or RTD inputs.

Its flexible software further allows flow calculation for liquids, gases, and steam, including compensation of pressure and/or temperature as well as more complex variables such as viscosity, discharge coefficient, thermal expansion factor, velocity of approach factor, and gas expansion factor. Digital integration with Honeywell control systems provides local measurement accuracy to the system level without adding typical analog-to-digital (A/D) and digital-to-analog (D/A) converter errors.

This product replaces the retired SMV3000 SmartLine Transmitter.

Key Specifications

  • Accuracy of up to 0.04% for differential pressure, up to 0.0375% for static pressure, up to 0.1°C for temperature and up to 0.6% for mass flow
  • Universal temperature input option
  • Built-in static pressure and temperature compensation
  • Rangeability of up to 400:1
  • Compensated flow response time of up to 2x per second
  • Multiple local display capabilities
  • Modular design and universal transmitter wiring
  • HART 7/DE protocol support
  • Built-in fail-safe feature for flow measurement

Specifications, Manuals, and Supporting Literature

Model Selection Guide

Use this table to find the right model for your application.  Don't see the option you need? Call a Lesman sales specialist at 800-953-7626

Description Catalog Number Availability
Measuring Range Differential Pressure Static Pressure    
-25" to 25" H2O 0 to 100 PSIA SMA810    
-400" to 400" H2O 0 to 1500 PSIA SMA845    
-400" to 400" H2O -14.7 to 4500 PSIG SMA870
Temperature RTD Input S1-
Universal Input (RTD & Thermocouple) S2-
Future No Digital Output 0-
Wetted Materials Plated Carbon Steel Process Head, 316L SS Diaphragm A_ _ _ _ _-
316L SS Process Head, 316L SS Diaphragm E_ _ _ _ _-
Hastelloy C-276 Process Head and Diaphragm J_ _ _ _ _-  
Monel 400 Process Head and Diaphragm L_ _ _ _ _-  
Fill Fluid Silicone Oil 200 _1_ _ _ _-
Fluorinated Oil CTFE _2_ _ _ _-  
Process Connection 1/4" NPTF Thread (Standard) _ _A_ _ _-
1/2" NPTF (for Carbon Steel/Stainless Steel Heads) _ _H_ _ _-
1/2" NPTF (for Hastelloy C-276 or Monel Heads) _ _H_ _ _-  
Vent/Drain Single-Ended Head, No Vent/Drain _ _ _ _1_-
Dual-Ended Head, Side Vent, End Plug _ _ _ _6_-
Gasket Teflon or PTFE (Glass-Filled) _ _ _ _ _A-
Viton or Fluorocarbon Elastomer _ _ _ _ _B-
Head Connection High Side Left, Low Side Right, Standard Orientation 1-
Low Side Left, High Side Right, Standard Orientation 2-
Approvals None 0
FM Approved A
CSA Approved B
Housing Aluminum Housing, 1/2" NPT Connection A_ _-
Aluminum Housing, 1/2" NPT Connection, Lightning Protection C_ _-
316 SS Housing, 1/2" NPT Connection E_ _-
316 SS Housing, 1/2" NPT Connection, Lightning Protection G_ _-
Output 4-20mA DC Analog Output, HART® v7 _H_-
4-20mA DC Analog Output, Honeywell DE Protocol _D_-
Interface No Indicator, No External Zero/Span _ _0-
No Indicator, External Zero/Span _ _A-
Indicator, External Zero/Span, English/Euro Languages _ _E-
Indicator, External Zero/Span, English/Asain Languages _ _J_
Software Standard Diagnostics 1_ _-
Failsafe/Write Protection Fail High (> 21.0 mA DC), Write Protect Disabled _1_-
Fail Low (< 3.6 mA DC), Write Protect Disabled _2_-
Fail High (> 21.0 mA DC), Write Protect Disabled _3_-
Fail Low (< 3.6 mA DC), Write Protect Disabled _4_-
Configuration Factory Standard _ _S-
Calibration Standard Accuracy, Factory Std Single Calibration Range A-
Mounting Bracket Carbon Steel Angle Bracket 1_ _ _-
Stainless Steel Angle Bracket 3_ _ _-
Tagging None _0_ _-
One-Wired SS Tag (Up to 4 Lines, 26 Char/Line) _1_ _-
Adapters No Conduit Plugs or Adapters Required _ _A0-
Options (Separate Option Choices with a Comma)
Certifications None 0
F3391 Certificate of Conformance F3
F3392 Overpressure Leak Test Certificate (1.5X MAWP) TP
Extended Warranty Additional 1 Year 01
Additional 2 Years 02
Additional 3 Years 03
Additional 4 Years 04
Additional 5 Years 05
Factory Factory Identification 0000

Videos

Subscribe to the Lesman Instrument Company YouTube channel.Lesman Instrument Company on YouTube

Video is a great way to learn about instruments and technology, and it's available whenever you need it. Watch step-by-step instructions on how to configure a transmitter, tune a controller, or troubleshoot a safety valve. We'll post videos we create, and those our manufacturer partners share with us, so you don't have to look in multiple places to find the video training you need.

Subscribe to Lesman's YouTube channel, and you'll get email notifications as soon as we add new training videos and webinars.