| Batch Controllers and Dispensers
| Flow Computers
| Flow Rate Totalizers | Level
Indicators | Pressure and Temperature Indicators
|
Use these tables to compare basic functions of the Fluidwell
F-Series indicators. When you've found the unit you want, click on
the model number to view a detailed spec sheet (where available).
Spec sheets are in Adobe PDF format, and range in size from 600K to
850K. For an easily printable version of the table below, get
the Fluidwell family brochure
(845K PDF). Click here to go back to our main
Fluidwell F-Series digital indicators page. Call Lesman at
800-953-7626 for current pricing and delivery information.
|
| Flow Rate Totalizers |
Linearization |
High/Low Alarms |
| Click for Specs |
F010 |
F011 |
F012 |
F014 |
F110 |
F111 |
F115 |
F016 |
F112 |
F118 |
F013 |
F113 |
| Buy Online at Lesman! |
|
|
 |
|
 |
|
|
|
|
|
|
|
| Function |
Flow rate
indicator |
Flow
totalizer |
Flow rate/
totalizer |
Pulsed input |
Pulsed and
analog output |
Two inputs,
two pulsed output |
Bi- directional measure- ment |
Pulse
outputs |
Pulse and
analog outputs |
Pulse and
analog outputs,
two flow rate alarms |
Flow rate
monitor, one alarm output |
Flow rate
monitor, max four alarm outputs |
| Intrinsically safe or explosion-proof |
|
|
|
|
|
|
|
|
|
|
|
|
| Backlight |
|
|
|
|
|
|
|
|
|
|
|
|
| Pulse, NAMUR, coil input |
|
|
|
|
|
|
|
|
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
|
|
|
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
|
|
|
|
|
|
|
| Actual total (resettable) |
|
|
|
|
|
|
|
|
|
|
|
|
Accumulated total
(non-resettable) |
|
|
|
|
|
|
|
|
|
|
|
|
| Actual flow rate |
|
|
|
|
|
|
|
|
|
|
|
|
| Pulse output assigned to total |
|
|
|
|
|
|
|
|
|
|
|
|
| Analog output (flow rate) |
|
|
|
|
|
|
|
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
|
|
|
|
|
|
|
| Multi-point linearization |
|
|
|
|
|
|
|
|
|
|
|
|
| High & low alarms |
|
|
|
|
|
|
|
|
|
|
|
|
| External reset total |
|
|
|
|
|
|
|
|
|
|
|
|
| Dual input |
|
|
|
|
|
|
|
|
|
|
|
|
| Flow direction detection |
|
|
|
|
|
|
|
|
|
|
|
|
Back to Top
|
Batch Controllers/Dispensers |
| Click for Specs |
F030 |
F130 |
F131 |
F133 |
F136 |
| |
One stage control output |
Two stage control or
pulse outputs |
Two control/pulse and
analog output |
Delivery controller with
batch counter |
Two control/pulse and
analog output |
| Intrinsically safe or explosion-proof |
|
|
|
|
|
| Backlight |
|
|
|
|
|
| Pulse, NAMUR, coil input |
|
|
|
|
|
| Actual total (resettable) |
|
|
|
|
|
| Accumulated Total (non-resettable) |
|
|
|
|
|
| One stage control output |
|
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
| Preset and actual value |
|
|
|
|
|
| Overrun correction |
|
|
|
|
|
| External start/stop |
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
| Pulse output assigned to total |
|
|
|
|
|
| Two stage control output |
|
|
|
|
|
| Actual flow rate |
|
|
|
|
|
| Analog output assigned to rate |
|
|
|
|
|
| Pulse output assigned to batch process |
|
|
|
|
|
| Batch controller |
|
|
|
|
|
| Ticket printing |
|
|
|
|
|
Back to Top
| Flow Computers |
Ratio |
Differential/sum |
| Click for Specs |
F126-EL |
F126-EG |
F114 |
F116 |
F127-EL |
| |
Flow and temperature for
liquid volume calculation |
Flow, temperature, and
pressure for gas volume calculation |
Ratio calculation
and monitoring |
Consumption/
sum calculation |
Consumption calculation
with temperature compensation |
| Intrinsically safe or
explosion-proof |
|
|
|
|
|
| Backlight |
|
|
|
|
|
| Pulse, NAMUR, coil input |
|
|
|
|
|
| Actual flow rate |
|
|
|
|
|
| Actual total (resettable) |
|
|
|
|
|
| Analog output (flow rate) |
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
| Accumulated total
(non-resettable) |
|
|
|
|
|
| Actual temperature |
|
|
|
|
|
| Temperature compensation |
|
|
|
|
|
| Dual input |
|
|
|
|
|
| Fuel compensation
calculation |
|
|
|
|
|
| Actual pressure |
|
|
|
|
|
| Pressure compensation |
|
|
|
|
|
| High & low alarms |
|
|
|
|
|
| Ratio calculation |
|
|
|
|
|
| Pulse output assigned to
total |
|
|
|
|
|
| Sum calculation (add on) |
|
|
|
|
|
Back to Top
| Level Indicators |
High/low alarms |
Linearization |
| Click for Specs |
F070 |
F073 |
F170 |
F077 |
F173 |
| Buy Online at Lesman |
 |
|
 |
|
|
| |
Level indicator |
One alarm output |
Analog and max
four alarm outputs |
One alarm output |
Analog and max
four alarm outputs |
| Intrinsically safe or explosion-proof |
|
|
|
|
|
| Backlight |
|
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
| Displays volume, height and percentage |
|
|
|
|
|
| High & low alarms |
|
|
|
|
|
| Analog output |
|
|
|
|
|
| Multi-point linearization |
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
Back to Top
| Pressure and Temperature
Indicators |
High/low alarm models |
| Click for Specs |
F040 |
F050 |
F141 |
F151 |
F043 |
F053 |
F143 |
F153 |
| Buy Online at Lesman |
 |
|
|
|
|
|
|
|
| |
Temperature indicator |
Pressure indicator |
Dual temperature indicator |
Dual pressure indicator |
One alarm output |
One alarm output |
Analog and max four alarm
outputs |
Analog and max four alarm
outputs |
| Intrinsically safe or explosion-proof |
|
|
|
|
|
|
|
|
| Backlight |
|
|
|
|
|
|
|
|
| 0-20 mA, 4-20 mA input |
|
|
|
|
|
|
|
|
| 0-10 V input |
|
|
|
|
|
|
|
|
| 100 ohm RTD (Pt100) |
|
|
|
|
|
|
|
|
Actual temperature and
engineering units |
|
|
|
|
|
|
|
|
Actual pressure and
engineering units |
|
|
|
|
|
|
|
|
| High & low alarms |
|
|
|
|
|
|
|
|
| RS-232, RS-485, TTL |
|
|
|
|
|
|
|
|
| Analog Output |
|
|
|
|
|
|
|
|
| Dual inputs |
|
|
|
|
|
|
|
|
Back to Top
|